Suntek Flush Door is a premium BWP grade door built to IS 2202 standard, bonded with PF resin and unique GCP (Glued Core Protection) technology for complete borer and termite resistance, backed by a 25-year warranty. Made from pinewood and hardwood with Gurjan face veneer for strength and aesthetics, it features a durable 50mm frame and double pressing for a stable, slam-impact resistant, uniformly calibrated finish.
| Size | 25, 30, 32, 35 and as per requirement |
|---|
Product Details
| TESTS | ISI REQUIREMENTS | OBSERVED VALUES |
|---|---|---|
| Dimension & Squareness Height Width Thickness, Min/Max Variation in thickness between any two points Squareness |
Tolerance: +5 mm +5 mm +1 mm Max.0.8 Deviation not more than 1mm per 500mm length |
+2 mm +2 mm 30.00 - 30.50mm 0.50mm 0.50mm |
| General Flatness | ||
| Twist | Max. 6 mm | Less than 6 mm |
| Cupping | Max. 6 mm | Less than 6 mm |
| Warping | Max. 6 mm | Less than 6 mm |
| Local Planeness | Max. 0.5 mm | 0.18 |
| No cracking, tearing or delamination. Indentation depth, max 0.2mm |
No cracking, tearing or delamination .0.14mm |
|
| Flexure Test (Deflection in mm) 15 minutes after 50 kg 3 minutes after load removal |
Deflection at maximum load not greater than 1/30th of length or 1/15th of width, whichever is less. Residual deflection not greater than 1/10 of maximum deflection. |
MD: Less than 1/30th of length & 1/15th of width. RD: Less than 1/10th of MD |
| Edge loading Test (deflection in mm) After 15 minutes of 100 kg loading 5 minutes after load removal Lateral buckling |
Deflection at maximum load not greater than 5 mm. Residual deflection after removal of load not greater than 0.5mm. Not more than 2mm during loading. No residual buckling after load removal. |
MD: Less than 5mm. RD: Less than 0.5mm Lateral Buckling: 0.1mm Conforms to the requirement |
| Shock Resistance Test Soft & light body impact Soft & heavy body impact |
No visible damage No visible damage |
Conforms to the requirement Conforms to the requirement |
| Slamming Test | No visible damage after 50 drops. | Conforms to the requirement |
| Glue adhesion Test | No delamination/ No single delamination of more than 50mm in length & more than 3mm in depth. |
Conforms to the requirement |
| End immersion Test | No delamination 8 cycle-1 day wet & 1 day dry |
Conforms to the requirement |
| Knife Test | Minimum Pass standard | Pass Standard |
| Screw withdrawal Test | Not less than 1000 N Surface condition: No visible damage to the surface either by delamination or extra chipping off |
3000 N Conforms to the requirement |
| Buckling test (deflection in mm) After 5 minutes of 40 kg loading 15 minutes after load removal |
No deterioration Initial Deflection not greater than 50mm Residual deformation after 15 minutes of unloading not greater than 5mm. |
Conforms to the requirement |
| Misuse test | No permanent deformation of the fixing or any other part of the door set in hindering. its normal working after the test. |
Conforms to the requirement |
| Varying humidity test | No visible warping, twisting or delamination. Maximum departure from the general planeness not more than 0.1mm. Recovery- At least 90% of the change in dimension. |